Technical guide

High-temperature dynamic pressure sensors: technologies, mounting and selection

A dynamic pressure sensor measures fast pressure variations: pulsations, combustion instabilities, compressor stall, shock waves. Once the measurement point exceeds a few hundred degrees, the sensor's electronics and materials become the weak point. This guide covers the available technologies, the ways to mount the sensor and the selection criteria.

Max. temperature (Alpheus UHT)
850 °C
Frequency band (Alpheus THT)
100 Hz – 400 kHz
Sensor head diameter
3.2 mm
Cooling required
None

What is a dynamic pressure sensor?

A static pressure sensor measures a stable or slowly varying pressure, such as that of a tank or a gas line. A dynamic pressure sensor, on the other hand, measures the fast fluctuations superimposed on that mean pressure, from a few hertz to several hundred kilohertz.

These fluctuations are often small compared with the static pressure, but they reveal a lot: a combustion instability, compressor stall, cavitation, a shock wave. They are expressed in pascals, in millibars or, as in acoustics, in decibels (dB SPL).

Many dynamic sensors, including Alpheus sensors, are vented: the static pressure equalizes on both sides of the membrane, which only sees the variations. The static pressure is therefore not limited, although it may change the frequency response, and measurement starts at around 100 Hz.

Reference points: decibels and pressure

LevelPressure (RMS value)Equivalent
140 dB SPL200 Pa2 mbar
160 dB SPL2 kPa20 mbar
180 dB SPL20 kPa0.2 bar
190 dB SPL63 kPa0.63 bar
194 dB SPL100 kPa1 bar
200 dB SPL200 kPa2 bar
210 dB SPL630 kPa6.3 bar
220 dB SPL2 MPa20 bar

Pressure = 20 µPa × 10^(level in dB / 20). These are RMS values: for a sine wave, the peak value is 1.41 times higher.

Why high temperature makes measurement harder

  • Electronics cannot keep up. Preamplifiers and integrated circuits cannot operate for long at several hundred degrees. They must be moved away from the hot spot or done without.
  • Sensing materials drift. The sensitivity of a piezoelectric crystal or a piezoresistive gauge varies with temperature, and sudden temperature changes can create spurious signals. Special materials and compensation are needed.
  • Cables must also survive. Above about 260 °C, manufacturers recommend special rigid cables instead of ordinary ones: bulkier, more expensive and harder to route.
  • Cooling complicates the installation. A water-cooled adapter or a purge circuit turns the measurement into a small installation, with its own risks of leaks and failures.
  • Electromagnetic interference adds up. Igniters, generators, motors and converters often surround hot spots. A weak electrical signal easily picks up noise there.

Dynamic pressure sensor technologies

Three families of sensors share high-temperature dynamic pressure measurement. None is best everywhere: the choice depends on temperature, bandwidth and environment.

PiezoelectricPiezoresistiveFiber optic (Alpheus)
PrincipleA crystal produces an electrical charge under pressureGauges on a silicon membrane change resistanceA membrane modulates the light sent back into the fiber
Static pressureNo, dynamic measurementYes, static and dynamicNo, vented sensor
High temperature without coolingSeveral hundred degrees with special crystals (gallium orthophosphate, langasite, tourmaline)Limited by the silicon gauges and their compensationUp to 850 °C: the limit comes from the head and fiber materials
Associated electronicsCharge amplifierPower supply, amplification and thermal compensationOptical conditioner, installed away from the hot area
LinkHigh-insulation cable, rigid cable at high temperatureMulti-conductor electrical cableA single fiber (multimode, sapphire or gold-coated depending on temperature)
Electromagnetic interferenceHigh-impedance signal, sensitiveWeak signal, needs shieldingImmune
Effect of temperature on sensitivityVariation to correct, spurious signals during thermal shocksDrift to compensateLess than 1% of sensitivity (Alpheus datasheets)

High-temperature piezoelectric sensors are a proven reference, especially for combustion. Fiber optics stand out when several constraints combine: heat, electromagnetic interference, limited space, long distance to the electronics.

Where and how to mount the sensor

At high temperature, the question is not only the sensor but where it is placed. There are three main approaches.

  • Flush mounting

    The sensor is screwed into the wall, membrane flush with the flow. This is the most faithful measurement, with no delay and no tube resonance. But the sensor is exposed to the full temperature.

  • Remote probe

    The sensor stays outside, connected to the measurement point by a long tube (a semi-infinite line). It is protected, but the tube attenuates and delays the signal, more so at higher frequencies, and it often has to be purged to keep hot gases out.

  • Cooled sensor

    A water-cooled adapter keeps the sensor at an acceptable temperature. The measurement stays close, but a reliable cooling circuit and more space are needed.

With an Alpheus sensor, the 3.2 mm head mounts directly flush with the wall, without cooling, up to 850 °C depending on the model. Only the fiber leaves the hot area.

Benefits of fiber optics at high temperature

  • No cooling

    With no electronics in the head, the limit is set by the materials: 350 °C for the Alpheus HT, 800 °C for the Alpheus THT (sapphire fiber), 850 °C for the Alpheus UHT (gold-coated fiber, ceramic adhesive).

  • Stable sensitivity

    According to our datasheets, the influence of temperature remains below 1% of sensitivity across the whole operating range.

  • Immune to interference

    Igniters, generators, converters, high voltage: light in the fiber is not affected by electric or magnetic fields.

  • Miniature

    A 3.2 mm diameter head (2.5 mm, or even 1.6 mm depending on the version) weighing 0.5 g, which barely disturbs the flow and fits into thin walls.

  • Electronics far from the hot spot

    The conditioner is installed in a control room or a protected room, connected to the sensor by the fiber.

  • No electrical energy at the measurement point

    No spark is possible at the sensor: an asset near fuels and in explosive atmospheres.

What to know before choosing

  • Dynamic measurement only. Alpheus sensors are vented: they do not measure static pressure. If you need it, add a static pressure sensor.
  • More robustness, less sensitivity. A sensor designed for high pressures and temperatures is less sensitive: the Alpheus HT has a self-noise of 50 dB SPL, the Alpheus THT 110 dB SPL. For small fluctuations, choose the most sensitive model compatible with your temperature.
  • The resonance frequency sets the bandwidth. On the Alpheus UHT, it can be chosen up to 1 MHz: the higher it is, the wider the frequency band, but the lower the sensitivity.
  • The optical link needs care. Clean connectors, the fiber's bend radius respected, the fiber mechanically protected where it passes through walls: as in telecoms, a neglected link reduces the light received and therefore the signal-to-noise ratio.

Applications

  • Combustion instabilities

    Gas turbines, combustion chambers, afterburners: detect pressure oscillations before they damage components.

    Learn more
  • Compressor stall

    Spot aerodynamic instabilities as close as possible to the blades, on test benches.

    Learn more
  • Hot ducts and pipes

    High-frequency acoustic waves in ducts, pipework and exhaust lines, in gases as well as water.

    Learn more
  • Detonics and shock waves

    Overpressures and shock fronts measured up close, with the electronics protected far from the test.

    Learn more
  • Nuclear

    Acoustic monitoring of equipment in irradiated areas, with the electronics outside the area.

    Learn more
  • Furnaces and materials

    Acoustic emission and crack monitoring in furnaces and on materials at very high temperature.

    Learn more
  • High voltage and welding

    Measurements near overhead lines, transformers and arc or HF welding processes, where an electrical sensor picks up too much interference.

    Learn more
  • Explosion-risk areas

    Dynamic pressure measurements with no electrical energy at the measurement point.

How to choose a high-temperature dynamic pressure sensor

Five questions narrow down the right model:

  1. 1

    What temperature at the measurement point, continuous and peak?

    Alpheus HT: −40 to 350 °C (420 °C short-term peak). Alpheus THT: −40 to 800 °C (850 °C short-term peak). Alpheus UHT: up to 850 °C.

  2. 2

    What pressure amplitude?

    Alpheus HT: up to 0.5 bar (about 190 dB SPL). Alpheus THT: up to 3 bar (about 203 dB SPL). Alpheus UHT: 130 to 220 dB SPL depending on the chosen resonance frequency. The decibel table above helps with the conversion.

  3. 3

    What frequency range?

    Alpheus HT: 100 Hz to 100 kHz. Alpheus THT: 100 Hz to 400 kHz. Alpheus UHT: resonance frequency of your choice, up to 1 MHz.

  4. 4

    What medium?

    Gases: Alpheus HT and THT. Water: Alpheus THT. Both withstand 100% relative humidity.

  5. 5

    What noise level is acceptable?

    For small fluctuations, pair the most sensitive sensor compatible with the temperature with a low-noise conditioner: typical dynamic range is 60 dB with MicroMyotis, 80 dB with Myotis and 100 dB with MiniMyotis.

Alpheus dynamic pressure sensors

ModelTemperatureFrequenciesMax. dynamic pressureFiber
Alpheus HT−40 to 350 °C (420 °C peak)100 Hz – 100 kHz0.5 bar (≈ 190 dB SPL)Multimode 50/125
Alpheus THT−40 to 800 °C (850 °C peak)100 Hz – 400 kHz3 bar (≈ 203 dB SPL)Sapphire 200 µm
Alpheus UHTUp to 850 °CResonance up to 1 MHz130 to 220 dB SPL depending on modelGold-coated, ceramic adhesive

Values taken from the datasheets. Heads 3.2 mm in diameter weighing 0.5 g (2.5 mm possible, 1.6 mm on some versions).

Alpheus sensors connect to a Phonoptics conditioner:

  • MiniMyotis: 1, 2, 4 or 8 channels, 3 MHz bandwidth, typical dynamic range of 100 dB
  • Myotis: portable, battery-powered, typical dynamic range of 80 dB
  • MicroMyotis: compact SFP+ module for volume integration

Calibration

Every Alpheus sensor is delivered calibrated for sensitivity and bandwidth. The frequency response is measured in the pressure field, from 100 Hz to 200 kHz, with a GRAS RA0014 electrostatic actuator that drives the membrane directly.

Temperature behavior is checked with our test equipment: an oven up to 300 °C and a furnace up to 1200 °C.

Our calibration equipment in detail

Frequently asked questions

What is the difference between static and dynamic pressure?

Static pressure is the mean value, stable or slowly varying, for example the pressure in a tank. Dynamic pressure refers to the fast fluctuations around that mean: pulsations, acoustic waves, shocks. A dynamic sensor is designed to follow these fluctuations, from a few hertz to several hundred kilohertz.

How do you convert dB SPL to bar?

Pressure in pascals = 20 µPa × 10^(level / 20). So 194 dB SPL is about 1 bar and 220 dB SPL is 20 bar, as RMS values. For a sine wave, the peak value is 1.41 times higher.

Can dynamic pressure be measured at 800 °C without cooling?

Yes. The Alpheus THT operates from −40 to 800 °C (850 °C short-term peak) and the Alpheus UHT up to 850 °C, with no cooling circuit: the head contains no electronics.

Does an Alpheus sensor measure static pressure?

No. It is vented: the static pressure equalizes on both sides of the membrane. It therefore withstands high static pressure with no set limit, although this may change its frequency response, but it does not measure it.

Is a special acquisition system needed?

No. The optical conditioner delivers an analog voltage, like a conventional sensor. It connects to your oscilloscope, acquisition card or data logger.

How is an Alpheus sensor mounted?

The 3.2 mm head mounts flush with the wall, directly in the medium to be measured. We work out the integration with you: drilling, sealing, fiber routing to the conditioner.

Do the sensors withstand humidity and water?

The Alpheus HT and THT withstand 100% relative humidity, and the Alpheus THT is compatible with water as well as gases.

Why a single fiber?

A single fiber carries the light both ways: the cable is thinner, passes through walls and sealed feedthroughs more easily, and is repaired with a single splice. The fiber is chosen for the temperature: multimode, sapphire or gold-coated.

A measurement point too hot for your current sensors?

Tell us about your installation: temperature, pressure amplitude, frequencies, access, distance to the acquisition system. We will suggest the right sensor, fiber and mounting.