Alpheus HT
- Frequency response
- 100 Hz – 100 kHz
- Temperature
- −40 → 350 °C
- Max. dynamic pressure
- 190 dB SPL
- Sensor head
- 3.2 × 10 mm
The Alpheus High-Temperature sensor is a dynamic fiber-optic pressure sensor specifically designed for extreme environments. Compact, lightweight, and robust, it offers high sensitivity and an extended frequency response up to 100 kHz, making it ideal for high-frequency acoustic analysis in ducts or closed systems. It is fully factory-calibrated.
Guide: all about the fiber-optic microphone
Guide: high-temperature dynamic pressure sensors
Main features
Main Features
- Transducer type: Silicon membrane
- Operating mode: Differential (front‑vented)
- Frequency response: 100 Hz – 100 kHz
- Natural frequency: > 100 kHz
- Max dynamic pressure: 0.5 Bar (≈ 190 dB SPL)
- Max static pressure: Unlimited (may affect frequency response)
- Damage threshold: > 1 Bar (≈ 200 dB SPL)
- Sensitivity: 0.3 mV/Pa (10 V/Bar)
- Directivity: Omnidirectional
- Self‑noise: 50 dB SPL (reduced to 40 dB SPL with low‑noise conditioner)
- Temperature range: -40 °C to 350 °C (420 °C short‑term peak)
- EMI/RFI immunity: Complete
- Sensor dimensions: 3.2 mm × 10 mm (also available at 2.5 mm)
- Weight: 0.5 g
- Fiber type: Multimode 50/125 OM2
- Standard cable length: 2 m
- Pressure media: All gases
- Calibration: Sensitivity and bandwidth, factory‑performed
Examples of available off-the-shelf sensors:
- Alpheus70
- Alpheus100
- Alpheus400
Operating temperature: -40°C to +350°C (polyimide fiber and polyimide adhesive)
Ambient operating pressure
Front-vented sensor
Use cases
Typical use cases
- Turbine analysis (compressor stall detection)
- Non‑destructive testing (NDT)
- High‑voltage measurements: overhead lines, electrical transformers
- Arc or high‑frequency welding processes
- Applications in ATEX (explosive or hazardous) environments
- Acoustic wave studies in ducts
Compare the Alpheus range
| Alpheus Standard | Alpheus HTThis product | Alpheus THT | Alpheus UHT | |
|---|---|---|---|---|
| Frequency band | up to 400 kHz | 100 Hz – 100 kHz | 100 Hz – 400 kHz | 1/3 of resonance frequency |
| Resonance frequency | 30 kHz – 1 MHz | > 100 kHz | — | 30 kHz – 1 MHz |
| Operating temperature | see datasheet | −40 → 350 °C (420 °C peak) | −40 → 800 °C (850 °C peak) | −40 → 850 °C |
| Max. pressure | 130 – 220 dB SPL | 190 dB SPL (dynamic) | 203 dB SPL (dynamic) | 130 – 220 dB SPL |