Acoustic & dynamic pressure measurement
Alpheus HT

Alpheus HT

Frequency response
100 Hz – 100 kHz
Temperature
−40 → 350 °C
Max. dynamic pressure
190 dB SPL
Sensor head
3.2 × 10 mm

The Alpheus High-Temperature sensor is a dynamic fiber-optic pressure sensor specifically designed for extreme environments. Compact, lightweight, and robust, it offers high sensitivity and an extended frequency response up to 100 kHz, making it ideal for high-frequency acoustic analysis in ducts or closed systems. It is fully factory-calibrated.

Main features

Main Features

  • Transducer type: Silicon membrane
  • Operating mode: Differential (front‑vented)
  • Frequency response: 100 Hz – 100 kHz
  • Natural frequency: > 100 kHz
  • Max dynamic pressure: 0.5 Bar (≈ 190 dB SPL)
  • Max static pressure: Unlimited (may affect frequency response)
  • Damage threshold: > 1 Bar (≈ 200 dB SPL)
  • Sensitivity: 0.3 mV/Pa (10 V/Bar)
  • Directivity: Omnidirectional
  • Self‑noise: 50 dB SPL (reduced to 40 dB SPL with low‑noise conditioner)
  • Temperature range: -40 °C to 350 °C (420 °C short‑term peak)
  • EMI/RFI immunity: Complete
  • Sensor dimensions: 3.2 mm × 10 mm (also available at 2.5 mm)
  • Weight: 0.5 g
  • Fiber type: Multimode 50/125 OM2
  • Standard cable length: 2 m
  • Pressure media: All gases
  • Calibration: Sensitivity and bandwidth, factory‑performed

Examples of available off-the-shelf sensors:

  • Alpheus70
  • Alpheus100
  • Alpheus400

Operating temperature: -40°C to +350°C (polyimide fiber and polyimide adhesive)

Ambient operating pressure

Front-vented sensor

Use cases

Typical use cases

  • Turbine analysis (compressor stall detection)
  • Non‑destructive testing (NDT)
  • High‑voltage measurements: overhead lines, electrical transformers
  • Arc or high‑frequency welding processes
  • Applications in ATEX (explosive or hazardous) environments
  • Acoustic wave studies in ducts

Compare the Alpheus range

Alpheus Standard Alpheus HTThis product Alpheus THT Alpheus UHT
Frequency bandup to 400 kHz100 Hz – 100 kHz100 Hz – 400 kHz1/3 of resonance frequency
Resonance frequency30 kHz – 1 MHz> 100 kHz—30 kHz – 1 MHz
Operating temperaturesee datasheet−40 → 350 °C (420 °C peak)−40 → 800 °C (850 °C peak)−40 → 850 °C
Max. pressure130 – 220 dB SPL190 dB SPL (dynamic)203 dB SPL (dynamic)130 – 220 dB SPL
Sensitivity1 µV/Pa – 5 mV/Pa0.3 mV/Pa1.5 µV/Pa1 µV/Pa – 5 mV/Pa
Request a quote