Technical guide
Fiber-optic microphone: principle, benefits and applications
A fiber-optic microphone measures sound with light. Its sensing head contains no electronics and no electrical current: a membrane sends back the light carried by the fiber, its vibrations modulate that light, and the conditioner converts it into a voltage. It therefore measures where an electrical microphone is disturbed, hazardous or destroyed.
- Electronics at the measurement point
- None
- Sensor-to-conditioner link
- 1 single fiber
- Max. temperature (Alpheus UHT)
- 850 °C
- Remote distance (Phantom)
- > 10 km
What is a fiber-optic microphone?
Every microphone converts a variation in acoustic pressure into a usable signal. In an electrical microphone (condenser, electret, dynamic or piezoelectric), this conversion happens at the measurement point: the head contains electrical components, often a preamplifier, and the signal travels back through a copper cable.
In a fiber-optic microphone, also called an optical microphone, the conversion happens elsewhere. The sensing head is purely mechanical and optical: a very thin membrane at the end of a fiber. Light travels to the head and back through the fiber, and all the electronics (light source, photodetector, amplification) sit in a separate unit, the conditioner, which can be installed several kilometers away.
As a result, nothing can disturb the signal at the measurement point, and the sensor disturbs nothing in return. There are no electronics to protect from heat, radiation or magnetic fields.
How does an optical microphone work?
At Phonoptics, a measurement takes four steps:
- 1
Emission
The conditioner sends stable infrared light into the optical fiber (1310 nm on MiniMyotis conditioners).
- 2
Reflection
At the end of the fiber, the light reaches a very thin silicon or silicon nitride membrane, which sends it back.
- 3
Modulation
The sound wave makes the membrane vibrate. These micro-displacements vary the light sent back into the same fiber, in step with the sound.
- 4
Conversion
In the conditioner, the modulated light is converted into an analog voltage that mirrors the acoustic pressure, which you record with your usual acquisition system.
- Single-mode
- Multimode
- Large core
- Rad-hard
- High temperature
- Metal-coated
One fiber for both directions. Many optical microphones use two fibers: one lights the membrane, the other collects the reflected light. At Phonoptics, the light returns through the fiber that brought it. The cable is thinner and cheaper, a break is repaired with a single splice, and bulkhead feedthroughs are simpler.
Micro-displacement or interferometry. There are two main families of fiber sensors. In the first, the amount of light sent back varies with the displacement of the membrane: this is the principle of Evotis microphones and Alpheus sensors. In the second, the membrane and the fiber end form a Fabry-Perot cavity, and the displacement is read from light interference: Phonoptics uses it for pressure measurement (Delphinus sensor, Fabry-Perus interrogator).
Optical or electrical microphone?
A fiber-optic microphone does not replace a conventional measurement microphone everywhere. It takes over where electronics at the measurement point become a problem.
| Fiber-optic microphone | Electrical microphone (condenser, electret, piezoelectric) | |
|---|---|---|
| Electronics at the measurement point | None: passive head | Electrical components, often a preamplifier |
| Electromagnetic interference | Immune: no electrical signal to disturb | Sensitive: shielding, filtering and grounding needed |
| Effect on what is measured | No current, no emissions | Can affect sensitive equipment (MRI, EMC tests) |
| MRI, strong magnetic fields | All-plastic version (Evotis Plastic) | Strong constraints whenever metal or electronics are present |
| Temperature at the measurement point | Up to 300 °C (Evotis microphone), 850 °C (Alpheus UHT sensor) | Limited by the electronics and head materials |
| Sensor-to-electronics distance | Several kilometers, negligible losses | Attenuation and noise grow with cable length |
| Explosive atmospheres | No electrical energy at the measurement point | Specific protection and certification |
| Setup | Optical conditioner, standard analog output | Preamplifier or IEPE supply, standard analog output |
| Best for | Heat, interference, radiation, MRI, long distances, covert listening | Routine measurements with no environmental constraints |
Benefits of the fiber-optic microphone
-
A clean signal next to motors and high voltage
Light picks up neither electric nor magnetic fields. The signal stays clean next to a transformer, a high-voltage line, an electric arc or a radio transmitter.
-
A sensor that does not interfere
With no current and no emissions, the microphone can listen to sensitive equipment (MRI, electromagnetic compatibility test) without skewing the result.
-
Right next to the heat
With no electronics in the head, the limit is set by the materials: 300 °C continuous for an Evotis microphone (350 °C peak), up to 850 °C for the Alpheus range.
-
Electronics safe, far from the measurement
The fiber carries the signal over several kilometers. The conditioner stays outside the area: control room, protected room, listening post.
-
No electrical energy at the measurement point
No spark is possible at the sensor: an asset in explosive atmospheres, pyrotechnics and detonics.
-
Small, light and rugged
An Alpheus head weighs 0.5 g with a 3.2 mm diameter, an Evotis microphone 2 g. They fit into a duct, a model or a wall.
What to know before choosing
- An optical conditioner is required. It plays the role of a conventional microphone's preamplifier: it supplies the light and converts the signal into a voltage. Each sensor needs one conditioner channel.
- The optical link needs some care. As in telecoms, connectors must be kept clean and the fiber's minimum bend radius respected: a dirty connection or an over-bent fiber reduces the light received, and therefore the signal-to-noise ratio.
- The fiber is chosen for the environment. Single-mode, multimode, large core, radiation-hardened, high-temperature or metal-coated: we choose it with you to suit the installation. The Alpheus THT, for example, uses a sapphire fiber to withstand 800 °C.
- The environment justifies it. For a lab measurement with no heat or interference, a few meters from the acquisition system, a conventional measurement microphone remains simpler and cheaper. The optical microphone comes into its own when those conditions no longer apply.
Applications
-
Engine and turbine testing
Dynamic pressure and acoustics as close as possible to combustion chambers, compressors and ducts, on test benches or on board.
Learn more -
Nuclear
Continuous acoustic monitoring in irradiated areas, with electronics outside the area and radiation-hardened fibers.
Learn more -
MRI and medical research
Recording a patient's voice during an MRI scan with an all-plastic microphone, with no metal or electronics in the scanner room.
Learn more -
High voltage and electric arcs
Listening to transformers and overhead lines, acoustic characterization of electric arcs for predictive maintenance.
Learn more -
Detonics and shock waves
Measuring overpressures and shock fronts with a miniature passive sensor, the electronics being protected far from the test.
Learn more -
Explosive atmospheres
Acoustic measurements in areas with an explosion risk, with no electrical energy at the measurement point.
-
Covert listening
A metal-free, unpowered and undetectable microphone, connected to its listening unit by more than 10 km of fiber (Phantom system).
Learn more -
Ultrasound and non-destructive testing
Acoustic emission, ultrasonic bath uniformity, crack monitoring in furnaces: up to 400 kHz with the Alpheus range.
Learn more
How to choose a fiber-optic microphone
Five questions are enough to narrow down the choice:
- 1
Which frequency range?
Audible sound (20 Hz to 15 kHz): Evotis microphones. Ultrasound, impulses and fast phenomena (up to 400 kHz): Alpheus sensors.
- 2
What maximum sound level?
An Evotis microphone measures up to 167 dB SPL. For very high levels (ducts, combustion, shock waves), Alpheus sensors range from 190 to 220 dB SPL depending on the model.
- 3
What temperature at the measurement point?
300 °C continuous (350 °C peak) with Evotis, 350 °C with Alpheus HT, 800 °C with Alpheus THT, 850 °C with Alpheus UHT.
- 4
What environment?
MRI and magnetic fields: Evotis Plastic. Measurement in water: Alpheus THT. Radiation: radiation-hardened fiber.
- 5
How many channels, and for what use?
Myotis: battery-powered portable conditioner, about 20 h of battery life. MiniMyotis: 1 to 8 channels, 3 MHz bandwidth. MicroMyotis: compact SFP+ module for volume integration.
Phonoptics microphones and acoustic sensors
| Model | Use | Frequencies | Temperature | Max. level |
|---|---|---|---|---|
| Evotis Standard | Microphone, audible sound | 20 Hz – 15 kHz | −40 to 300 °C (350 °C peak) | 167 dB SPL |
| Evotis HT | High-temperature microphone | Audible range | Up to 350 °C | — |
| Evotis Plastic | All-plastic microphone, MRI | 20 Hz – 15 kHz | −20 to 65 °C | 167 dB SPL |
| Alpheus Standard | Acoustic pressure, ultrasound | Up to 400 kHz | Up to 125 °C | 220 dB SPL |
| Alpheus HT | Dynamic pressure, high temperature | 100 Hz – 100 kHz | −40 to 350 °C | 190 dB SPL |
| Alpheus THT | Very high temperature, gases and water | 100 Hz – 400 kHz | Up to 800 °C | 203 dB SPL |
| Alpheus UHT | Ultra-high temperature | Resonance up to 1 MHz | Up to 850 °C | 220 dB SPL |
| Phantom | Covert listening, over 10 km of fiber | 150 Hz – 10 kHz | — | — |
Values taken from the datasheets. Details and datasheets are on each product page.
All these sensors connect to a Phonoptics conditioner:
- Myotis: portable, battery-powered, with USB audio output
- MiniMyotis: 1, 2, 4 or 8 channels, 3 MHz bandwidth, noise reduction up to 20 dB
- MicroMyotis: compact SFP+ module for volume integration
Manufacturing and calibration
The sensors are assembled at our premises in Évry-Courcouronnes, France. The silicon and silicon nitride membranes are produced in a clean room by a company specializing in microfabrication, which ensures repeatability from one sensor to the next.
Each sensor is calibrated in house for sensitivity and frequency response:
- sensitivity at 1 kHz, at 94 and 114 dB, with a B&K type 4231 acoustic calibrator;
- free-field response from 100 Hz to 10 kHz in a B&K type 4232 anechoic test box;
- pressure-field response from 100 Hz to 200 kHz with a GRAS RA0014 electrostatic actuator;
- temperature testing in an oven up to 300 °C and a furnace up to 1200 °C.
Frequently asked questions
Is a fiber-optic microphone really immune to electromagnetic interference?
Yes. The signal travels as light in a glass fiber, which picks up neither electric nor magnetic fields. Only the conditioner contains electronics, and it can be placed far from the source of interference.
Can an optical microphone be used in an MRI scanner?
Yes, with a metal-free model. The Evotis Plastic is made entirely of plastic and is used in particular to record speech during an MRI scan. The conditioner stays outside the scanner room, connected to the microphone by the fiber.
What temperature can a fiber-optic microphone withstand?
It depends on the head materials, since the head contains no electronics. At Phonoptics: 300 °C continuous (350 °C peak) for the Evotis microphone, and up to 850 °C for the Alpheus UHT acoustic pressure sensor.
How much fiber can there be between the sensor and the conditioner?
Losses in the fiber are very low: several kilometers are possible. The Phantom listening system works with more than 10 km of fiber between the microphone and its electronic unit.
Is a special acquisition system needed?
No. The conditioner delivers an analog voltage, like a conventional sensor. You connect it to your oscilloscope, acquisition card or data logger, and keep your usual software.
Microphone or dynamic pressure sensor: what is the difference?
Both measure fast pressure variations. A microphone is used for audible sound at ordinary levels (up to 167 dB SPL for the Evotis), and a dynamic pressure sensor for very high levels and ultrasound, for example in a duct or a combustion chamber (up to 220 dB SPL and 400 kHz for the Alpheus range).
Why one fiber rather than two?
With a single fiber, the cable is thinner and cheaper per meter, a break is repaired with a single splice, and bulkhead or sealed feedthroughs are simpler. The fiber can also be of any type, chosen for your environment.
Are the sensors calibrated?
Yes. Each sensor is calibrated at our premises, for sensitivity and frequency response, before delivery.
An acoustic measurement project in a harsh environment?
Tell us about your application: frequencies, levels, temperature, distance, installation constraints. We will suggest the right sensor, fiber and conditioner.
Read also: High-temperature dynamic pressure sensors · Why fiber? · Technology · Industries